Main -> Heating units, refrigerating units -> Temperature controllers -> CO2 incubators |
CO2 Incubators with Automatic Sterilisation, Memmert |
CO2 Incubators INCOmed
Basic model Venting and control systems: - homogeneous atmosphere and temperature distribution in interior chamber due to encapsulated, turbulence-free ventilation system
- adaptive, fuzzy-supported, multi-functional, digital PID-micro-processor control
- self-diagnostics system for error finding for temperature and CO2-control as well as for humidity limitation control
- 2 Pt100-sensors of DIN-class A in 4-conductor measurement with alternating monitoring and function adaption at exactly the same temperature value
- digital real-time week programme-clock with day group function, adjustable precisely to the minute
- digital display of all temperature, weekday, time, CO2-, humidity and set-up default values - language selection via set-up
- CO2-supply via sterile filter
- digitalised electronic CO2 control with automatic zero position (NDIR-measurement system) - adjustable range 0-10% - adjustable accuracy 0.1%
- intrinsic setting of height above sea level
- interruption of CO2-supply when door is opened
- tenth-precise digital target value specifications and current value display (LED) of temperature values and CO2-concentration
- integrated humidity limitation control (88-97% rh) with digital display of relative humidity - display resolution 0.5%, adjustment accuracy 1%
- saving the programme process in case of power failure
- Chip-card (STERICard) for sterilisation of interior with fixed values (4 hrs/160°C) without removing sensors and internal fixtures
Heating concept: - big multi-functional allround-heating with additional door and back-wall heating to avoid condensate formation
- incl. factory calibration certificate at +37°C
Multi-overheat protection: - with acoustic and optical alarm when temperature is exceeded or fallen below
- separated, electronic temperature selection monitor TWW, protection class 3.1 can be set digitally
- additional integrated protection from excess and insufficient temperature "ASF", which automatically follows the target value in selectable distance
- mechanical temperature limitation TB protection class 1 to turn off heating at ca. 10°C above the max. chamber temperature
- additional monitoriing: Acoustic signal when CO2 limit is exceeded and gas bottle is empty; door-open warning
Structure stainless-steel housing: - fully insulated stainless-steel door with double lock and 4-point adjustment
- inner glass door with opening (8 mm Ø) to remove gas sample
- fully galvanised steel-panel back wall
Interior: - easy-to-handle stainless-steel workspace enforced by deep-drawing ribbing W.-St. 1.4301 (ASTM 304), hermetically welded
- stainless perforated steel plates, full width (size 108: 2 pc., sizes 153/246: 3 pc), stainless steel water basins (sizes 108/153: 1 pc. full width, size 246: 2 pc. half width)
Temperature range: - from +20°C (but at least 8°C above room temperature) to +50°C
- temperature deviation at 37°C: < ±0.3°C
Power:
| Type | Outer W × H × D mm | Useful W × H × D mm | Vol. approx. l | Wght approx. kg | P rating approx. W | Order No. | |
(1) | INCO108med | 710×778×550 | 560×480×400 | 108 | 70 | 1000 | 41 26 50001 | |
(2) | INCO153med | 630×938×650 | 480×640×500 | 153 | 80 | 1500 | 41 26 50003 | |
| INCO246med | 790×938×750 | 640×640×600 | 246 | 110 | 2000 | 41 26 50002 | |
Variable through adjustable feet. Interior depth minus 25 mm for circulation shaft in the middle
Options
Communication module
USB interface; "Celsius" software with extended functions for control and recording of temperature, CO2, O2 (for O2 module) and relative humidity; internal log memory 1024 kB as a ring memory for all setpoints, actual values, errors; settings with real-time and date; logging approx. 3 months with 1 min. memory interval; parallel printer interface for all PCL3-compatible printers
CO2 module
extended CO2 range of 0 – 20%
Comfort module
for size 108/153/246, two gas connections with quick-coupling, automatic gas bottle changeover (cannot be used with the O2 module)
Hygiene module
Electropolished, jointlessly laser-welded working space
Humidity module
for size 108/153/246, active microprocessor, humidification and dehumidification (40 – 97% rh), incl. digital indication and self-diagnosis system; moisture supply with distilled water from an external container; dehumidification via sterile filter (standard moisture restriction regulation and water trays are no longer required)
O2 module
for size 108/153/246, oxygen content is controlled by means of supply of nitrogen; setting range 1% to 20% O2, setting accuracy 0.1% (cannot be combined with Comfort and Premium modules). For applications with an O2 setpoint smaller than 10%, we urgently advise to equip the device with a Humidity module.
Premium module
comprises comfort, hygiene, communication, and CO2 modules (cannot be combined with the O2 module)
Accessories
| Article | Order No. | |
| 4-fold divider for interior chamber with gas shade for size 246 | 10 26 04030 | |
| Replacement of 3 plates (full width) by 6 plates (half width) | |
| Stainless steel shelves, perforated, for type 108/110/160 | 10 26 04031 | |
| Extra stainless steel shelf, perforatet, for size 153, full width | 10 26 04033 | |
| Extra stainless steel shelf, perforatet, for size 246, full width | 10 26 04034 | |
| Extra stainless steel shelf, perforatet, for size 246, half width | 10 26 04035 | |
| Extra water dish 108, full width | 10 26 04032 | |
| Extra water dish 153, full width | 10 26 04036 | |
| Extra water dish 246, half width | 10 26 04037 | |
| CO2 pressure reducing valve | 10 26 04042 | |
| to DIN 8546, incl. gas cylinder monitor | |
| O2 pressure reducing valve | 10 26 04041 | |
| to DIN EN ISO 2503, incl. gas cylinder monitor | |
| IQ check list | 10 26 02521 | |
| with works test data as support for validation by customer | |
| OQ checklist | 10 26 01018 | |
| with cabinet-related factory data, for one freely selectable CO2, humidity, and temperature value; includes temperature distribution measurement for 27 measuring points pursuant to DIN 12880:2007-05 as support for validation at the customer side | |
| Celsius FDA-Edition | 41 26 11013 | |
| Software conforming to FDA (no domain network support) | |
| Oven-related user authorization card | 41 26 11021 | |
| prevents undesired manipulation by unauthorized third parties | |
| Start-up and brief training (Germany only) through Memmert service | 10 26 04012 | |
Additional options
The following options are only possible in combination with the Communication and Premium modules.
| Article | Order No. | |
| Ethernet interface instead of USB | 10 26 04024 | |
| incl. Software "Celsius Ethernet Edition" | |
| RS232 interface instead of USB | 10 26 04021 | |
| RS485 interface instead of USB | 10 26 04022 | |
| USB connection cable for computer interface | 10 26 04023 | |
Contact us to inquire about additional accessories, for example heated duct in the rear wall, additional flexible Pt100, HEPA interior filter, lockable doors, substructures etc. We reserve the right to make changes in technical specifications. Dimensions subject to confirmation. All performance data are typical mean values for serial devices. Some of the illustrations in the publication include accessories (at extra cost).
|
|
|