Main -> Heating units, refrigerating units -> Temperature controllers -> Circulator baths |
Process Thermostats, LAUDA |
Process thermostats Integral XT
With their high heating, cooling and pump capacities, LAUDA Integral XT process thermostats create a new thermostating dimension in process engineering. The basic principle comprises a circulation thermostat with a very small internal volume and anon-perfused expansion vessel. - High resolution graphic LC display
- Real-time clock combined with timer function
- Editable programmer for up to 150 segments in five programs
- Nine pre-defined sets of parameters can be selected for the control
- Menu-driven operation in German, English, French or Spanish
- Function lights for heating, cooling and external control
- Error reports by means of LED lights, acoustic alarm and clear text message
- Variopump with 8 steps and adjustable limit of the pump pressure
- Integrated external control with cascade connection
- Supply temperature limit for gentle heating of the external system
- Integrated opto-decoupled RS 232/485 interface as standard
Process thermostats Integral XT – High-temperature thermostats
| Type | Temp. range °C | Temp. accur. ± K | Heater cap. kW | Cooler cap. kW | Pump pressure bar | Flow rate l/min | Order No. | |
| XT 4 H | 80 – 320 | 0.05 | 3.5 | — | 2.9 | 45 | 10 23 32147 | |
| XT 8 H | 80 – 320 | 0.05 | 8 | — | 2.9 | 45 | 10 23 32549 | |
| XT 4 HW | 30 – 320 | 0.1 | 3.5 | 161) | 2.9 | 45 | 10 23 32148 | |
| XT 8 HW | 30 – 320 | 0.1 | 8 | 161) | 2.9 | 45 | 10 23 32550 | |
1) Cooling output (water counter-cooling)
Process thermostats Integral T
Integral T are extremely efficient process thermostat in a compact design. As generalists for fast, precise thermostating in the external circuit, they easily master the most demanding tasks. - Programmer with max. 150 temperature/time segments
- Parallel display of 2 temperature values with a resolution of 0.1 °C
- Discharge pressure display
- External control via Pt 100 temperature probe or standard signal
- User calibration and LAUDA 2-point calibration
- Analogue inputs (3) and outputs (2), e.g. for control system. Can be configured to 0 to 10 V or 0/4 to 20 mA
- Malfunction indication for low level, overtemperature, pumps and cooling compressor
- Remote "malfunction" display via neutral contact
- Stand-by switch via neutral contact
- RS 232/485 interface for PC and LAUDA Wintherm Plus control software
| Type | Temp. range °C | Temp. accur. ± K | Heater cap. kW | Cooler cap. kW | Pump pressure bar | Flow rate l/min | Order No. | |
| T 1200 | -25 – 120 | 0,2 | 2,25 | 1,2 | 3,2 | 40 | 10 23 30101 | |
| T 1200 W | -25 – 120 | 0,2 | 2,25 | 1,6 | 3,2 | 40 | 10 23 30102 | |
(3) | T 2200 | -25 – 120 | 0,2 | 2,25 | 2,2 | 3,2 | 40 | 10 23 30103 | |
| T 2200 W | -25 – 120 | 0,2 | 2,25 | 2,7 | 3,2 | 40 | 10 23 30104 | |
| T 4600 | -30 – 120 | 0,2 | 6 | 4,6 | 3,2 | 40 | 10 23 30205 | |
| T 4600 W | -30 – 120 | 0,2 | 6 | 5,5 | 3,2 | 40 | 10 23 30206 | |
| T 7000 | -30 – 120 | 0,3 | 6 | 7 | 6 | 60 | 10 23 30207 | |
| T 7000 W | -30 – 120 | 0,3 | 6 | 8,5 | 6 | 60 | 10 23 30208 | |
| T 10000 | -30 – 120 | 0,3 | 9 | 10 | 6 | 60 | 10 23 30209 | |
| T 10000 W | -30 – 120 | 0,3 | 9 | 13 | 6 | 60 | 10 23 30210 | |
|
|
|