Main -> Heating units, refrigerating units -> Temperature controllers -> Tube furnaces |
Tube furnaces, Nabertherm |
Compact tube furnace series R 50/250/12 - R 120/1000/13 + Mini tube furnaces RD 15 – 30
These compact tabletop tube furnaces with integrated control systems can be used universally for many processes. - Tmax 1200°C or 1300°C
- Casing made of textured stainless steel sheets (non-rusting design)
- Outer tube diameter of 50 to 120 mm, heated length from 250 to 1000 mm
- Working tube of C 530 ceramic including two fibre plugs as standard equipment
- Type S thermocouple
- Silent solid-state power control relays
- Digital PID-controller B 180 with one free programmable ramp, holding temperature and holding time or professionel controller P 330 with 9 free adjustable programs and 4 holding ramps and 4 holding times per program + interface RS 422
- Supplied with choice of digital R 6 controller with storable holding temperature (RD modesl only), PID B 180 controller with one free programmable ramp, holding temperature and holding time or professionel P 330 controller with 9 freely adjustable programs and 40 segments, RS interface
Options: - Over-temperature limit controller with adjustable cutout temperature for thermal protection class 2 in accordance
with EN 60519-2 as temperature limiter to protect the oven and load - Cascade controller for temperature measurement in the working tube and behind the tube
- Working tubes designed for process requirements
- Three-zoned design with HiProSystem control (heated length from 750 mm, for 1300°C models)
- Gas supply package for protective gas or vacuum operation on request
| Type | Vers. | Tmax °C | Outer W × D × H mm | Tubing O.D. mm | heated L mm | L. continuous temp. ΔT 10k mm | Tube L mm | Connec. V/kW | Order No. | |
| RD 30/250/11 | R6 | 1100 | 350×196×348 | | 250 | | | /1,5 | 10 04 24720 | |
| RD 30/200/13 | R6 | 1300 | 350×196×348 | | 250 | | | /1,5 | 10 04 24740 | |
| R 50/200/12 | B 180 | 1200 | 400×240×490 | 50 | 250 | 80 | 450 | 230/1,2 | 10 04 24800 | |
| R50/500/12 | B 180 | 1200 | 650×240×490 | 50 | 500 | 170 | 700 | 230/1,8 | 10 04 24810 | |
| R 100/750/12 | B 180 | 1200 | 1000×360×640 | 90 | 750 | 250 | 1070 | 230/3,6 | 10 04 24820 | |
| R 120/1000/12 | B 180 | 1200 | 1300×420×730 | 120 | 1000 | 330 | 1400 | 400/6,0 | 10 04 24830 | |
| R 50/250/12 | P 330 | 1200 | 400×240×490 | 50 | 250 | 80 | 450 | 230/1,2 | 10 04 24805 | |
| R 50/500/12 | P 330 | 1200 | 650×240×490 | 50 | 500 | 170 | 700 | 230/1,8 | 10 04 24815 | |
| R 100/750/12 | P 330 | 1200 | 1000×360×640 | 100 | 750 | 250 | 1070 | 230/3,6 | 10 04 24825 | |
| R 120/1000/12 | P 330 | 1200 | 1300×420×730 | 120 | 1000 | 330 | 1400 | 400/6,0 | 10 04 24835 | |
| R 50/250/13 | B 180 | 1300 | 400×240×490 | 50 | 250 | 80 | 450 | 230/1,2 | 10 04 24850 | |
| R 50/500/13 | B 180 | 1300 | 650×240×490 | 50 | 500 | 170 | 700 | 230/1,8 | 10 04 24860 | |
| R 100/750/13 | B 180 | 1300 | 1000×360×640 | 90 | 750 | 250 | 1070 | 230/3,6 | 10 04 24870 | |
| R 120/1000/13 | B 180 | 1300 | 1300×420×730 | 120 | 1000 | 330 | 1400 | 400/6,5 | 10 04 24880 | |
| R 50/250/13 | P 330 | 1300 | 400×240×490 | 50 | 250 | 80 | 450 | 230/1,2 | 10 04 24855 | |
| R 50/500/13 | P 330 | 1300 | 650×240×490 | 50 | 500 | 170 | 700 | 230/1,8 | 10 04 24865 | |
| R 100/750/13 | P 330 | 1300 | 1000×360×640 | 90 | 750 | 250 | 1070 | 230/3,6 | 10 04 24875 | |
| R 120/1000/13 | P 330 | 1300 | 1300×420×730 | 120 | 1000 | 330 | 1400 | 400/6,5 | 10 04 24885 | |
Universal tube furnace series RT 50-250/11 - RT 30-200/15
These compact tube furnaces are used when laboratory experiments must be performed horizontally, vertically, or at specific angles. - Tmax 1100 °C, 1300 °C, or 1500 °C
- Compact design
- Vertical or horizontal operation freely adjustable
- Working height freely adjustable
- Working tube made of C 530 ceramic
- Type S thermocouple
- Operation also possible separate from stand if safety guidelines are observed
- Control system built into furnace base
- Digital PID-controller B 180 with one free programmable ramp, holding temperature and holding time or professionel controller P 330 with 9 free adjustable programs and 4 holding ramps and 4 holding times per program + interface RS 422
| Type | Vers. | Tmax °C | Outer W × D × H mm | Tubing I.D. mm | heated L mm | L. continuous temp. ΔT 10k mm | Tube L mm | Connec. V/kW | Order No. | |
| RT 50-250/11 | B 180 | 1100 | 350×380×740 | 50 | 250 | 80 | 360 | 230/1,8 | 10 04 29150 | |
| RT 50-250/13 | B 180 | 1300 | 350×380×740 | 50 | 250 | 80 | 360 | 230/1,8 | 10 04 29210 | |
| RT 30-200/15 | B 180 | 1500 | 445×475×740 | 30 | 250 | 70 | 360 | 230/1,8 | 10 04 29700 | |
| RT 50-250/11 | P 330 | 1100 | 350×380×740 | 50 | 250 | 80 | 360 | 230/1,8 | 10 04 29155 | |
| RT 50-250/13 | P 330 | 1300 | 350×380×740 | 50 | 250 | 80 | 360 | 230/1,8 | 10 04 29220 | |
| RT 30-200/15 | P 330 | 1500 | 445×475×740 | 30 | 250 | 70 | 360 | 230/1,8 | 10 04 29710 | |
Hinged tube furnace series RS 80/300/11 - RS 170/1000/11
Tube furnaces can be used for either horizontal or vertical operation. Using a variety of accessories, these professional tube furnaces can be optimally laid out for your process. - Tmax 1100°C or 1300°C
- Casing made of sheets of textured stainless steel (non-rusting design)
- Tmax 1100°C: Type K thermocouple
- Tmax 1300°C: Type S thermocouple
- Available in horizontal or vertical designs
- Hinged design for simple insertion of the working tube
- Working tube with max. diameter made of ceramic C 530 for operation in air included in scope of delivery. Smaler tubes on request
- Switching and control unit separate from furnace in own wall or standing cabinet
- Available in horizontal or vertical design
- Digital PID-controller B 150 with one free programmable ramp, holding temperature and holding time or professionel controller P 300 with 9 free adjustable programs and 4 holding ramps and 4 holding times per program optional with interface RS 422
Options: - Cascade controller with temperature measurement in the working tube and in the oven chamber behind the tube
- Working tubes designed for process requirements
- Different gas supply packages for protective gas and vacuum operation
- 3-zone control for optimization of temperature uniformity
- Burst protector for heating elements and/or as support surface for the load
- Stand for vertical operation
| Type | Vers. | Tmax °C | Outer W × D × H mm | Tubing O.D. mm | heated L mm | L. continuous temp. ΔT 10k mm | Tube L mm | Connec. V/kW | Order No. | |
| RS 80/300/11 | B 150 | 1100 | 555×475×390 | 80 | 300 | 100 | 650 | 230/1,8 | 10 04 22100 | |
| RS 80/500/11 | B 150 | 1100 | 755×475×390 | 80 | 500 | 170 | 850 | 230/3,4 | 10 04 22200 | |
| RS 80/750/11 | B 150 | 1100 | 1005×475×390 | 80 | 750 | 250 | 1100 | 400/4,6 | 10 04 22300 | |
| RS 120/500/11 | B 150 | 1100 | 755×525×440 | 120 | 500 | 170 | 850 | 400/4,8 | 10 04 22400 | |
| RS 120/750/11 | B 150 | 1100 | 1005×525×440 | 120 | 750 | 250 | 1100 | 400/6,3 | 10 04 22500 | |
| RS 120/1000/11 | B 150 | 1100 | 1255×525×440 | 120 | 1000 | 330 | 1350 | 400/9,0 | 10 04 22600 | |
| RS 170/750/11 | B 150 | 1100 | 1005×575×490 | 170 | 750 | 250 | 1100 | 400/11,5 | 10 04 22700 | |
| RS 170/1000/11 | B 150 | 1100 | 1255×575×490 | 170 | 1000 | 330 | 1350 | 400/11,5 | 10 04 22940 | |
| RS 80/300/11 | P 300 | 1100 | 555×475×390 | 80 | 300 | 100 | 650 | 230/1,8 | 10 04 22110 | |
| RS 80/500/11 | P 300 | 1100 | 755×475×390 | 80 | 500 | 170 | 850 | 230/3,4 | 10 04 22210 | |
| RS 80/750/11 | P 300 | 1100 | 1005×475×390 | 80 | 750 | 250 | 1100 | 400/4,6 | 10 04 22310 | |
| RS 120/500/11 | P 300 | 1100 | 755×525×440 | 120 | 500 | 170 | 850 | 400/4,8 | 10 04 22410 | |
| RS 120/750/11 | P 300 | 1100 | 1005×525×440 | 120 | 750 | 250 | 1100 | 400/6,3 | 10 04 22510 | |
| RS 120/1000/11 | P 300 | 1100 | 1255×525×440 | 120 | 1000 | 330 | 1350 | 400/9,0 | 10 04 22610 | |
| RS 170/750/11 | P 300 | 1100 | 1005×575×490 | 170 | 750 | 250 | 1100 | 400/11,5 | 10 04 22710 | |
| RS 170/1000/11 | P 300 | 1100 | 1255×575×490 | 170 | 1000 | 330 | 1350 | 400/11,5 | 10 04 22945 | |
|
|
|