Certified UV/Vis calibration standards for spectrophotometers To supply accurate results over the long run, spectrophotometers need to be calibrated in regular intervals. To this end, the Hellma Analytics calibration lab certified pursuant to DIN EN ISO 17025 offers ready-to-use, DAkkS certified calibration standards. Using UV/Vis calibration standards from the accredited Hellma calibration lab guarantees that the calibration operations performed are traceable to the NIST (National Institute of Standards and Technology) primary standards and the standards of the major pharmacopoeias (EP, DAB, USP). The certified Hellma Analytics reference materials provide the user with a clean, easy, and efficient solution for checking the spectrophotometer. Outside dimensions (H×W×D): 48 mm × 12.5 mm × 12.5 mm
1 Glass filters sets
for inspection of the spectrophotometers in respect of wavelength accuracy and photometrical accuracy
| Type | Contents | Wavelength nm | Order No. | |
| 666-S000 | Holmium oxide glass filter 666-F1 Neutral density filter 666-F2, 0.25 abs. Neutral density filter 666-F3, 0.5 abs. Neutral density filter 666-F4, 1.0 abs. Filter holder F0, empty as reference | 279, 361, 453, 536, 638 440; 465; 546,1; 590; 635 440; 465; 546,1; 590; 635 440; 465; 546,1; 590; 635 | 10 55 16660 | |
| 666-S001 | Neutral density filter 666-F3, 0.5 abs. Neutral density filter 666-F4, 1.0 abs. Didymium glass fliter 666-F7, 0.5–1.0 abs. | 440; 465; 546,1; 590; 635 440; 465; 546,1; 590; 635 Wavelength accuracy: 329, 472, 512, 681, 875 Photometrical accuracy: 270, 280, 297, 320, 340 | 10 55 16663 | |
| 666-S002 | Neutral density filters 666-F2/-F3/-F4 | 440; 465; 546,1; 590; 635 | 10 55 16662 | |
2 Liquid filters sets
for inspection of the spectrophotometers in respect of stray light behavior, resolution power, photometrical accuracy and wavelength accuracy pursuant to the European Pharmacopoeia
| Type | Use | Contents | Wavelength nm | Order No. | |
| 667-UV100 | Testing for stray light | Liquid filter UV1, potassium chloride Reference filter UV12, purified water | Cut-off 200 | 10 55 16678 | |
| 667-UV200 | Testing the spectral resolution | Liquid filter UV6, toluene in hexane Reference filter UV9, hexane | Scan from 265-270 | 10 55 16676 | |
| 667-UV305 | Testing the photometric accuracy | Liquid filter UV60, potassium dichromate 60 mg/l Liquid filter UV600, potassium dichromate 600 mg/l Reference filter UV14, perchloric acid | 235, 257, 313, 350 430 | 10 55 16672 | |
| 667-UV005 | Testing the wavelength accuracy | Liquid filter UV5, holmium oxide in perchloric acid | 241, 287, 361, 536, 640 | 10 55 16679 | |
| 667-UV003 | Complete set | Type 667-UV100/UV200/UV305/UV005 | | 10 55 16677 | |
|
|
|