Main -> Optical investigations -> Spectroscopy -> Cuvettes, accessories
Secondary Calibration Standards for Spectrophotometers, Hellma®

Certified UV/Vis calibration standards for spectrophotometers
To supply accurate results over the long run, spectrophotometers need to be calibrated in regular intervals. To this end, the Hellma Analytics calibration lab certified pursuant to DIN EN ISO 17025 offers ready-to-use, DAkkS certified calibration standards. Using UV/Vis calibration standards from the accredited Hellma calibration lab guarantees that the calibration operations performed are traceable to the NIST (National Institute of Standards and Technology) primary standards and the standards of the major pharmacopoeias (EP, DAB, USP).
The certified Hellma Analytics reference materials provide the user with a clean, easy, and efficient solution for checking the spectrophotometer.
Outside dimensions (H×W×D): 48 mm × 12.5 mm × 12.5 mm

1 Glass filters sets

for inspection of the spectrophotometers in respect of wavelength accuracy and photometrical accuracy

TypeContentsWavelength
nm
Order No.
666-S000Holmium oxide glass filter 666-F1
Neutral density filter 666-F2, 0.25 abs.
Neutral density filter 666-F3, 0.5 abs.
Neutral density filter 666-F4, 1.0 abs.
Filter holder F0, empty as reference
279, 361, 453, 536, 638
440; 465; 546,1; 590; 635
440; 465; 546,1; 590; 635
440; 465; 546,1; 590; 635
10 55 16660
666-S001Neutral density filter 666-F3, 0.5 abs.
Neutral density filter 666-F4, 1.0 abs.
Didymium glass fliter 666-F7, 0.5–1.0 abs.
440; 465; 546,1; 590; 635
440; 465; 546,1; 590; 635
Wavelength accuracy: 329, 472, 512, 681, 875
Photometrical accuracy: 270, 280, 297, 320, 340
10 55 16663
666-S002Neutral density filters 666-F2/-F3/-F4440; 465; 546,1; 590; 63510 55 16662


2 Liquid filters sets

for inspection of the spectrophotometers in respect of stray light behavior, resolution power, photometrical accuracy and wavelength accuracy pursuant to the European Pharmacopoeia

TypeUseContentsWavelength
nm
Order No.
667-UV100Testing for stray lightLiquid filter UV1, potassium chloride
Reference filter UV12, purified water
Cut-off 20010 55 16678
667-UV200Testing the spectral resolutionLiquid filter UV6, toluene in hexane
Reference filter UV9, hexane
Scan from 265-27010 55 16676
667-UV305Testing the photometric accuracyLiquid filter UV60, potassium dichromate 60 mg/l
Liquid filter UV600, potassium dichromate 600 mg/l
Reference filter UV14, perchloric acid
235, 257, 313, 350
430
10 55 16672
667-UV005Testing the wavelength accuracyLiquid filter UV5, holmium oxide in perchloric acid241, 287, 361, 536, 64010 55 16679
667-UV003Complete setType 667-UV100/UV200/UV305/UV00510 55 16677