Main -> Measuring systems -> Temperature -> Laboratory thermometers
ASTM Thermometers, Amarell

ASTM precision thermometers, white backed.
The following list shows just a selection of the types available. All ASTM thermometers (including those not listed) are available ex stock.
ASTM thermometers, calibratable, without factory certificate:

ASTM numberASTM designationMeasuring range
°C
Grad.
°C/°F
Order No.
1 CPartial immersion-20 – +150116 10 10001
2 CPartial immersion-5 – +300116 10 10002
3 CPartial immersion-5 – +400116 10 10003
5 CCloud and Pour-38 – +50116 10 10005
6 CLow cloud and pour-80 – +20116 10 10006
7 CLow distillation-2 – +300116 10 10007
8 CHigh distillation-2 – +400116 10 10008
9 CLow Pensky-Martens-5 – +1100.516 10 10009
10 CHigh Pensky-Martens+90 – +370216 10 10010
11 CCleveland Open Flash-6 – +400216 10 10011
12 CDensity - Wide range-20 – +1020.216 10 10012
13 CLoss on heat+155 – +1700.516 10 10013
14 CWax melting point+38 – +820.116 10 10014
15 CLow softening point-2 – +800.216 10 10015
16 CHigh softening point+30 – +2000.516 10 10016
17 CSaybolt viscosity+19 – +270.116 10 10017
18 CReid vapor pressure+34 – +420.116 10 10018
19 CSaybolt viscosity+49 – +570.116 10 10019
20 CSaybolt viscosity+57 – +650.116 10 10020
21 CSaybolt viscosity+79 – +870.116 10 10021
22 COxidation stability+95 – +1030.116 10 10022
28 F1)Kinematic viscosity+97.5 – +102.52)0.12)16 10 10028
30 F1)Kinematic viscosity+207.5 – +212.52)0.12)16 10 10030
33 CLow aniline point-38 – +420.216 10 10033
34 CMedium aniline point+25 – +1050.216 10 10034
35 CHigh aniline point+90 – +1700.216 10 10035
36 CTiter test-2 – +680.216 10 10036
37 CSolvents distillation-2 – +520.216 10 10037
38 CSolvents distillation+24 – +780.216 10 10038
39 CSolvents distillation+48 – +1020.216 10 10039
40 CSolvents distillation+72 – +1260.216 10 10040
41 CSolvents distillation+98 – +1520.216 10 10041
42 CSolvents distillation+95 – +2550.516 10 10042
44 C1)Kinematic viscosity+18.6 – +21.40.0516 10 10044
45 C1)Kinematic viscosity+23.6 – +26.40.0516 10 10045
46 C1)Kinematic viscosity+48.6 – +51.40.0516 10 10046
47 C1)Kinematic viscosity+58.6 – +61.40.0516 10 10047
54 CCongealing point+20 – +100.60.216 10 10054
56 CBomb calorimeter+19 – +350.0216 10 10056
57 CTag Closed Tester, +Low Range-20 – +500.516 10 10057
61 CPetrolatum melting point+32 – +1270.216 10 10061
62 CPrecision-38 – +20.116 10 10062
63 CPrecision-8 – +320.116 10 10063
64 C1)Precision+25 – +550.116 10 10064
65 C1)Precision+50 – +800.116 10 10065
69 C1)Precision+195 – +3050.516 10 10069
71 COil in wax-37 – +210.516 10 10071
90 CSolidification point0 – +300.116 10 10090
91 CSolidification point+20 – +500.116 10 10091
99 FWeathering test-58 – +412)0.52)16 10 10099
102 CSolvents distillation+123 – +1770.216 10 10102
103 CSolvents distillation+148 – +2020.216 10 10103
107 CSolvents distillation+248 – +3020.216 10 10107
112 C1)Solidification point of benzene+4 – +60.0216 10 10112
114 CAviation Fuel Freezing Point-80 – +200.516 10 10114
120 C1)Kinematic viscosity+38.6 – +41.40.0516 10 10120
121 C1)Kinematic viscosity+98.6 – +101.40.0516 10 10121
127 C1)Kinematic viscosity-21.4 – -18.60.0516 10 10127



1) Thermometer with auxiliary scale at 0°C and +32°F
2) =°F