Main -> Measuring systems -> Electrochemistry -> pH meters |
Laboratory pH Meters, Knick |
Laboratory pH Meters
The 766 laboratory pH meter is designed for standard applications in everyday lab operation. Gaincheck® performs a complete instrument check. At a keystroke it not only checks electrical characteristics, but also display and keypad. After power-on, a quick check automatically tests instrument operability. Drycheck® monitors electrode impedance and alerts to electrode dry-up even in standby mode. Sensoface® checks the electrode system and informs on electrode condition by evaluating the electrode’s zero point, slope, response time and glass impedance. Trueline® delivers a calibrated analog recorder signal. Calimatic® automatically recognizes the correct buffer. This allows calibration at a stroke of a key, providing ease of use and safety. EMC design protects the instrument from electromagnetic interferences.
Technical data: |
Ext. dimensions (W×H×D): | 244 × 95 × 255 mm |
Weight: | approx. 2 kg |
Case: | glass-reinforced polyamide12, rust-proof stainless steel cover, protection type IP 54, prepared for fitting the ZU 6954 attachment stand |
Connected load: | 230 V~ -15% + 10%, 48 to 62 Hz, < 10 VA, optional 115 V~ (opt. 363) |
Display: | alphanumeric, 2 × 4 digits, 14-segment LED, 13 mm high characters, Sensoface® 3 status indicators |
Ranges: |
pH: | -2,00 to +16,00 |
mV: | -1999 to +1999 |
°C: | -50,0 to +150,0 |
Measurement error: |
pH: | < 0,01 |
mV: | < 0,1% + 0,3 mV |
°C: | < 0,3 K |
Input resistance: | > 1 × 1012 Ω |
Input current: | < 1 × 10-12 A |
Temperature coefficient: | < 0,1 digit/K |
Temperature compensation: | Pt 1000, manual -50.0 to +100.0°C |
Input: | DIN 19 262 |
Analog output: | pH compensated |
Trueline®: | 1 mV/ mV 100 mV/pH |
EMC directive: | 89 / 336 / EEC |
Standards: | EN 61326 / VDE 0843 Part 20 2002-3 |
| Article | Order No. | |
| Laboratory pH meter 766 | 61 60 76600 | |
| incl. power cable, without electrode, 3 years warranty | |
| Laboratory pH meter 766 SET A, with mains cable | 61 60 76601 | |
| with power cable and SE 101 N pH/Pt 1000 combination electrode (plastic, 110 mm) | |
| Laboratory pH meter 766 SET B, with mains cable | 61 60 76602 | |
| with power cable and SE 100 N pH/Pt 1000 combination electrode (glass, 165 mm) | |
Accessories
| Article | Order No. | |
| Attachment stand ZU 6954 | 61 60 96954 | |
| for accommodating the immersion stirrer and any 3 probes, for connecting directly to the pH meter / conductivity meter | |
| Immersion stirrer ZU 6955 | 61 60 96955 | |
| power supplied via ZU 6956 power supply unit | |
| Power supply unit ZU 6956 for immersion stirrers | 61 60 96956 | |
| Measuring probe, pH/Pt 1000 combination electrode SE 100 N | 61 60 97100 | |
| glass with integrated Pt 1000 temp. sensor, pH 0 to 14, 0 to 80°C | |
| Measuring probe, pH/Pt 1000 combination electrode SE 101 N | 61 60 97101 | |
| plastic with integrated Pt 1000 temp. sensor, pH 0 to 14, 0 to 80°C | |
| Measuring probe, pH combination electrode SE 103 N | 61 60 97103 | |
| glass without temperature sensor, pH 0 to 14, 0 to 100°C | |
| Pt 1000 temperature probe ZU 6959 | 61 60 96959 | |
| for temperature measurements with short adjustment time, stainless steel, -10 to +100°C | |
| Buffer solution NIST (NBS) buffer set ZU 6941 | 61 60 96941 | |
| Option 363 | 10 60 90363 | |
| auxiliary power 115 V AC | |
|
|
|