Main -> Measuring systems -> Electrochemistry -> Conductivity meters
Laboratory Conductivity Meters, Knick
Laboratory Conductivity Meter

703 laboratory conductivity meter with 4-electrode cell.

With the 703 laboratory conductivity meter you can use either 4-electrode or 2-electrode cells. The measuring input is automatically switched over to the appropriate operating mode. Temperature compensation takes place either automatically with the Pt 100 or Pt 1000 temperature probes or manually.

The standard equipment RS 232 interface allows immediate further processing of the measured values by computer. Also connecting a printer is no problem. Records of the parameter settings, the calibration and the unit diagnostics can be output directly to a printer. This provides you with comprehensive GLP-compatible documentation at the press of a button. The unit automatically selects the display range with the greatest possible resolution. Naturally, the desired display range can also be specified manually. The large, bright LED display allows simultaneous readout of two measured values, e. g. conductivity and temperature. The 14-segment display can show alphanumeric

 

Technical data:

External (W×H×D):

244 × 95 × 255 mm

Weight:

approx. 2 kg

Case:

glass-reinforced polyamide 12,
rust-proof stainless steel cover, protection type IP 54,
prepared for fitting the ZU 6954 attachment stand

Power supply:

230 V~ -15% + 10%, 48 to 62 Hz,
< 10 VA, optional 115 V~ (opt. 363)

Display:

alphanumeric, 2 × 4 digits, 14-segment LED, 13 mm high characters, 3 status indicators with Sensoface

Ranges:

Cond:

0,000 to 9,999 µS/cm
0000 to 9999 mS/cm
-50.0 to +150.0

Measurement error:

Cond.:

< 0,5% of MV ±2 digit

°C:

< 0,3 K

Resolution:

to 0,001µS/cm

Reproducibility:

< 0,1% of measured value

Temperature compensation:

-50 to +150°C
Pt 100/Pt1000 (autom. selection)
or manual, linear TC characteristic 0,00 to 9.99%/K,
reference temperature 20°C/25°C selectable

Permissible cell constant:

0,001 to 199,9 cm-1, adjustable

Cell standardization:

operating modes
- automatic by cell constant determination with NaCl or KCl solution
- direct entry of cell constant

Monitoring
of sensor
and meter (GLP):

Sensoface® provides information
- for selection of 2-electrode cells
- on too great a difference between reference and measuring temperature
- for handling of 4-elec trode cells
- in case of clock memory loss
- in case of irregular checking of measuring equipment

Unit self-test:

test of measuring electronics including recorder output, segment and keypad test, RAM, EPROM and EEPROM

GLP records:

parameter settings, calibration, unit diagnostics (DIN ISO 9000), galvanically isolated

Analog output:

Cond.:

1 mV/µS·cm-1
1 mV/mS·cm-1

°C:

10 mV/°C

Interface:

RS 232

Printer control:

for ZU 0244 printer or any other standard printer with serial interface

EMC directive:

89 / 366 / EEC

Standards:

EN 61326 / VDE 0843 Part 20 2002-3

4-electrode cell:

Ranges:

1 µS/cm to 1 S/cm
-20°C to +100°C

System carrier:

glass

Ring electrodes (4):

platinum, bright

Sheath tube:

dia. 16 mm KPG® glass, replaceable

Immersion depth (min/max):

60/80 mm

Temperature probe:

Pt 1000, fast responding

Time constant:

approx. 1 cm-1

Connection cable:

approx. 1 m



ArticleOrder No.
Laboratory conductivity meter 70361 60 70300

incl. power cable, without cell, 3-year warranty



Accessories
ArticleOrder No.
4-electrodes sensor, body glass (adapter ZU 0290 required)61 60 96985
Calibration solution (1 ampoule for 0.1 mol/l NaCl solution)61 60 96945
Pt 1000 temperature probe ZU 695961 60 96959

for temperature measurements with short adjustment time,
stainless steel, -10 to +100°C

Spare sheath tube ZU 0180 for cell61 60 97180
Attachment stand ZU 695461 60 96954

for accommodating the immersion stirrer and any 3 probes, for connecting directly to the pH meter / conductivity meter

Interface cable ZU 015261 60 97152

for connecting to a computer
(EMC special cable)

Interface cable ZU 024561 60 97245

for connecting to a printer
(EMC special cable)

Laboratory printer ZU 024461 60 97244
Printing paper ZU 024961 60 97249

for ZU 0244 laboratory printer (5 rolls)

Color ribbon ZU 025061 60 97250

for ZU 0244 laboratory printer (5 pcs)

Option 36310 60 90363

auxiliary power 115 V AC