Triple safety aspects
- One door only can be opened at a time. If one door is open, the other is automatically locked.
- If the autoclave is switched off or if no current is available (e.g. power failure), both doors remain locked.
- If the door at the non-sterile side is opened, a sterilization program hast o be performed before the door at the sterile side can be opened.
The locking system can be adapted to customers' wishes. Doors and control panel are made of heat-insulating plastic, the housing completely of stainless steel and the stainless steel edges specially processed for smooth junctions with walls. Operation, however, can be carried out from both sides, the position (open or closed) of
the opposite door being indicated on the display.
For use under the most stringent clean room and safety conditions
- For biological safety laboratories. Fitting as a sterilization and pass-through lock for protecting the external environment.
- For clean rooms in laboratories and production facilities as a sterilization and pass-through lock separating sterile and non-sterile areas.
Standard Features | Systec HX |
Integrated, separate steam generator | • |
Housing, support frame and pressure vessel made of corrosion-resistant stainless steel | • |
Temperature and pressure range 140°C, 4 bar | • |
Touch-Screen control | • |
Number of sterilization programs | Up to 100 |
Code-secured access rights for changing parameters and further safety-relevant intervention | • |
Internal memory for storing up to 500 sterilization cycles | • |
Timer for starting programs | • |
Autofill: automatic demineralized water feed for steam generation | • |
Flexible PT-100 temperature sensor | • |
Additional temperature sensor in condense exhaust | • |
Temperature holding function for liquids after program finish | • |
Special program for Durham tubes | • |
Calculation of F0 value | • |
Special program for waste sterilization with pulsed heat-up for more efficient air exhaust | • |
Water-cooled steam exhaust, thermostatically controlled | • |
Programmable automatic door-opening on completion of program | • |
RS-232 and RS-485 interfaces for external data transmission (network-compatible) | • |
Available options | |
Extension of temperature and pressure ranges to 150 °C / 5 bar (from chamber volume 65 liters to 650 liters) | + |
Options for process optimization | |
Rapid cooling for efficient and safe cooling of liquids | + |
Vacuum system for validatable sterilization of solids and waste materials in disposal bags | + |
Superdry: for drying solids (only in combination with optional vacuum system) | + |
Exhaust filtration (including condensate inactivation) for safe sterilization of hazardous biological substances | + |
Options for documentation | |
Integrated printer for batch documentation | + |
PC software for comprehensive documentation | + |
AuditTrail: unalterable and traceable documentation | + |
Systec autoclaves are delivered ready for subsequent installation of all options. Further options and special programs as well as baskets and inserts, transport and loading systems on request. |