Main -> Special analysis -> Water, environment -> Photometric workplaces, field investigations
Photometers, WTW
photoLab® series

Precise thanks to the high-quality lens system and fast thanks to barcode test recognition with automatic cuvette detection system. These instruments require little maintenance thanks to their exceptional photometric stability and wear-free design.
Extensive on-board AQS/IQK guarantees reliable results during measurement and documentation. Values can be read off as concentration, extinction or transmission.
More than 200 programmed methods with all essential settings for test sets are available for downloading and updating at any time from the Internet. The methods include all common parameters for CSB, analysis of sewage and drinking water, also for sea water and for pisciculture and fish farming. Users are thus provided with both a high-quality and economical solution for everything from routine measurements to laboratory analysis. All photometers feature date and time and come with an RS 232 interface. 2 years warranty.

 

photoLab® S6

photoLab® S12

Applications

Routine measurements in
waste and drinking water,
battery version optional

Routine measurements in
waste and drinking water,
comprehensive laboratory
tests, battery
version optional

Wavelengths

6 wavelengths: 340,
445, 525, 550,
605, 690 nm

12 wavelengths:
340, 410, 445, 500, 525,
550, 565, 605, 620,
665, 690, 820 nm

Own methods

no

50

Cuvettes

Round 16 mm

Round 16 mm; rect-
angular 10, 20, 50 mm

Extinction range

0.3 to 3.2

0.3 to 3.2

Measured value memory

500

500



ArticleOrder No.
(1)Photometer photoLab S 680 81 32013

for routine measurements with the convenient cuvette tests

 
ArticleOrder No.
(2)Photometer photoLab S1280 81 32024
  • round and rectangular cuvettes for measuring also low concentrations and for using the more economical reagent tests
  • 50 own method places for convenient measuring of own analyses
  • kinetics function
  • economical allround photometer in each laboratory through 12 wavelengths


Spectrophotometers VIS and UV/VIS: photoLab® 6000 series

The combination of systematic and spectral analysis:
For the analysis of standard parameters, such as for sewage and drinking water, in combination with the functions for extensive spectral measurements and stepless scan setting of 190 / 320 – 1100 nm. Spectra, multiple wavelength measurements and kinetics tests can conveniently be done, as well as routine measurements!

Spectral analysis from 190 – 1100 nm

  • Absorption spectra
  • Kinetics measurements
  • Multiple wavelength measurements incl. special methods and ADMI colorimetry
  • 20 user profiles (each) and calculation methods (max. 50) can be saved

Systematic analysis with commercial test records

  • Over 200 methods for standard parameters in analysis on sewage and drinking water, with CSB-determination, direct methods such as SAK at 354 nm and reagent-free methods such as colouring
  • Bar code recognition for test records in round and rectangle cuvettes
  • Automatic cuvette recognition for 16, 10, 20 and 50 mm without adapter change
  • 100 user-defined methods
  • Timer, up to 3 parallel

AQS:

  • Multi-step AQS with user administration and extensive test means for photometer and used test records. The AQS-functions can be retrieved directly via function keys in the respective measurement mode.
  • Calibration intervals for device and test records (time or number of measurements)
  • Photo check: user-guided check of the zero point, bar code reading facility, 3 wavelengths at 4 measurement points (linearity)
  • Grey filter
  • UV/VIS-standard solutions (e.g. holmium oxide solution)
  • Specifications for control standard for standard parameters including tolerance specifications
  • Matrix check and increase procedure with measurement value calculation and retrieval rates

Batch certificates ensure the quality of each individual test batch and help with saving the plausibility of results.

Data management
2 USB interfaces provide data exchange (by USB-stick or via USB-hub in a bigger PC environment). The exchange is bi-directional and makes simple handling for saving and updating possible:

  • Measurement data records and PDF files
  • Spectra and kinetics data
  • Software updates
  • Method updates
  • PC-software for data management

By means of a bar code reader, also uncoded tests and sample names can be read. In addition, an RS 232 interface provides another connection to peripheral devices.

User-friendly operation

  • User guidance on the screen
  • Function keys F1-F4 for quick working with menu-dependent function assignment
  • Frequent functions in direct access (Print, Save)
  • Automatic list of favourites for test record
  • Selection lists
  • Data filter for selective data editing
ArticleOrder No.
(3)photoLab® 6100 VIS10 81 20201

Spectral photometers for systematic and spectral analysis from 320-1100 nm (specify power supply)

(4)photoLab® 6600 UV-VIS10 81 20202

Spectral photometers for systematic and spectral analysis from 190-1100 nm (specify power supply)



5 Mobile colorimeters: the pHotoFlex® series

The colorimeters of this series convince by their sophisticated technology for use on site, comprising an optional LabStation for easy evaluation and execution of laboratory tasks. A large illuminated graphic display guides the user through all functions. A laboratory station with battery and charging function is available as an accessory for the the basic battery-operated model (4 AA batteries). Routine data measurement and evaluation can then be performed even more conveniently with an external scanner and evaulation software.

pHotoflex®STD
For all those who only need photometry functions: more than 150 methods.

pHotoflex®pH
Colorimeter with electrochemical pH and redox option. Additional methods for ammonia and carbon dioxide.

pHotoFlex®Turb
Same as pHotoFlex pH, plus turbidity measurement from 0 to 1100 NTU / FNU.

Photometer functions

  • 6 wavelengths: 436, 517, 557, 594, 610, 690 nm, LEDs with filter, accuracy < 2 nm
  • Extinction range: 0 – 2 E
  • 2 cuvette sizes for a large range of concentration: 28 mm, 16 mm; variable cuvette height from 91 to 104 mm for the 16 mm cuvette
  • Up to 200 method-related data for a large number of test sets, extendible over the Internet, for drinking- and waste water analytics, CSB determination
  • Data memory for 1000 measurements
  • 100 own methods
  • Coloring measurement according to EN ISO 7887 (exactly 436 nm, 517 nm, 610 nm)

pH functions

  • pH meter with temperature compensation and 3-point calibration
  • pH -2.00 to 16.00 (+/- 0.01), temperature: -5.0 to 100.0 °C
  • Automatic buffer recognition: TEC / NIST

Turbidity functions

  • IR LED according to DIN 27027/ISO 7027
  • Measuring range: 0-1100 NTU / FNU
  • Resolution: 0-9.99 NTU: 0.01; 10-99 NTU: 0.1; 100-1100 NT: 1.0
  • 3-point calibration with standards (0.02 – 10 – 1000 NTU)
ArticleOrder No.
pHotoFlex STD, incl. batteries (4 AA)10 81 21105
pHotoFlex pH pocket photometer, incl. batteries (4 AA)80 81 51100
pHotoFlex Turb pocket photometer, incl. batteries (4 AA)80 81 51110


Accessories
ArticleOrder No.
pHotoFlex rechargeable battery80 81 51300

Rechargeable battery + mains plug for all pHotoFlex models

LabStation80 81 51301

Laboratory station with pHotoFlex software for all pHotoFlex models, incl. rechargeable battery and mains cable, laboratory interface cable (9-pole)

  • simplified operation for routine measurements
  • more functionality (barcode support)
  • better input and output of data through pHotoFlex software
Interface cable AK540/B80 81 52842

Unit/PC (6-pole) via RS232



Accessories pH
ArticleOrder No.
pH combination electrode SenTix 4161 81 21635
pH combination electrode SenTix 41-361 81 21636
pH buffer TPL461 81 21800
pH buffer TPL761 81 28802


6 Reagents for photoLab® and photoFlex® series
ArticleModelMeasuring rangeOrder No.PU
pc/Pack
Al aluminium RT1)148250.020-1.20 mg/l Al80 81 25425300
NH4 ammonium RT1)147520.010-3.00 mg/l NH4-N80 81 25426500
NH4 ammonium KTA60.20-8.00 mg/l NH4-N10 81 2507225
Pb lead RT1)097170.010-5.00 mg/l Pb80 81 2503450
Cadmium RT1)017450.002-0.500 mg/l Cd80 81 2505155
Cadmium KT148340.025-1.000 mg/l Cd80 81 2531425
Chlorine KT free005950.03-6.00 mg/l Cl280 81 25419200
Chlorine KT free + total005970.03-6.00 mg/l Cl280 81 25420200
Chlorine dioxide RT1)006080.020-10.00 mg/l ClO280 81 25017200
Chromate KT145520.05-2.00 mg/l Cr80 81 2534125
Cyanide KT145610.010-0.500 mg/l CN80 81 2534425
Cyanide RT1)2)097010.002-0.500 mg/l CN80 81 25492100
COD KTC310-150 mg/l CSB10 81 2507025
COD KTC425-1500 mg/l CSB10 81 2507125
Iron RT1)14761/10.005-5.00 mg/l Fe80 81 254351000
Iron RT1)14761/20.005-5.00 mg/l Fe80 81 25439250
Fluoride RT1)2)145980.10-20.0 mg/l F80 81 25048100
Total hardness KT009610.7-30.1 °d80 81 2503925
Copper RT1)147670.02-6.00 mg/l Cu80 81 25441250
Magnesium KT008155.0-75.0 mg/l Mg80 81 2504325
Manganese KT008160.01-10.0 mg/l Mn80 81 2503525
Manganese RT1)14770/10.10-5.00 mg/l Mn80 81 25442500
N total KT145370.5-15.0 mg/l Ntotal80 81 2535825
Nitrate KT145420.5-18.0 mg/l NO3-N80 81 2541025
Nitrate RT1)2)147730.2-20.0 mg/l NO3-N80 81 25444100
Nitrite RT1)14776/10.005-1.000 mg/l NO2-N80 81 254451000
Nitrite RT1)14776/20.005-1.000 mg/l NO2-N80 81 25440335
Nitrate KT2)N20,5-25 mg/l NO2-N10 81 2507325
Nitrite KTN50,01-0,7 mg/l NO2-N10 81 2507425
Ozone RT1)00607/10.010-4.00 mg/l O380 81 25016200
Ozone RT1)00607/20.010-4.00 mg/l O380 81 250541200
Phosphate RT1)148420.5-30,0 mg/l PO4-P80 81 25447400
Phosphate RT1)14848/10.01-5.00 mg/l PO4-P80 81 25446420
Phosphate KT (Ptotal)P60,05-5,00 mg/l PO4-P
0,05-1,50 mg/l Pges
10 81 2507525
Phosphate KTP70.3-15.0 mg/l PO4-P
0.3-15.0 mg/l Pges
10 81 2507625
Sulfate KT145485,0-250 mg/l SO480 81 2541425
Zinc RT1)2)148320.05-2.50 mg/l Zn80 81 2545190



Other tests on request, method data can be updated from the Internet.
1) not for photoLab S6
2) not for pHotoFlex®