Main -> Special analysis -> Water, environment -> Photometric workplaces, field investigations |
Photometers, WTW |
photoLab® series
Precise thanks to the high-quality lens system and fast thanks to barcode test recognition with automatic cuvette detection system. These instruments require little maintenance thanks to their exceptional photometric stability and wear-free design. Extensive on-board AQS/IQK guarantees reliable results during measurement and documentation. Values can be read off as concentration, extinction or transmission. More than 200 programmed methods with all essential settings for test sets are available for downloading and updating at any time from the Internet. The methods include all common parameters for CSB, analysis of sewage and drinking water, also for sea water and for pisciculture and fish farming. Users are thus provided with both a high-quality and economical solution for everything from routine measurements to laboratory analysis. All photometers feature date and time and come with an RS 232 interface. 2 years warranty.
| photoLab® S6 | photoLab® S12 |
Applications | Routine measurements in waste and drinking water, battery version optional | Routine measurements in waste and drinking water, comprehensive laboratory tests, battery version optional |
Wavelengths | 6 wavelengths: 340, 445, 525, 550, 605, 690 nm | 12 wavelengths: 340, 410, 445, 500, 525, 550, 565, 605, 620, 665, 690, 820 nm |
Own methods | no | 50 |
Cuvettes | Round 16 mm | Round 16 mm; rect- angular 10, 20, 50 mm |
Extinction range | 0.3 to 3.2 | 0.3 to 3.2 |
Measured value memory | 500 | 500 |
| Article | Order No. | |
(1) | Photometer photoLab S 6 | 80 81 32013 | |
| for routine measurements with the convenient cuvette tests |
| |
| Article | Order No. | |
(2) | Photometer photoLab S12 | 80 81 32024 | |
| - round and rectangular cuvettes for measuring also low concentrations and for using the more economical reagent tests
- 50 own method places for convenient measuring of own analyses
- kinetics function
- economical allround photometer in each laboratory through 12 wavelengths
|
Spectrophotometers VIS and UV/VIS: photoLab® 6000 series
The combination of systematic and spectral analysis: For the analysis of standard parameters, such as for sewage and drinking water, in combination with the functions for extensive spectral measurements and stepless scan setting of 190 / 320 – 1100 nm. Spectra, multiple wavelength measurements and kinetics tests can conveniently be done, as well as routine measurements! Spectral analysis from 190 – 1100 nm - Absorption spectra
- Kinetics measurements
- Multiple wavelength measurements incl. special methods and ADMI colorimetry
- 20 user profiles (each) and calculation methods (max. 50) can be saved
Systematic analysis with commercial test records - Over 200 methods for standard parameters in analysis on sewage and drinking water, with CSB-determination, direct methods such as SAK at 354 nm and reagent-free methods such as colouring
- Bar code recognition for test records in round and rectangle cuvettes
- Automatic cuvette recognition for 16, 10, 20 and 50 mm without adapter change
- 100 user-defined methods
- Timer, up to 3 parallel
AQS: - Multi-step AQS with user administration and extensive test means for photometer and used test records. The AQS-functions can be retrieved directly via function keys in the respective measurement mode.
- Calibration intervals for device and test records (time or number of measurements)
- Photo check: user-guided check of the zero point, bar code reading facility, 3 wavelengths at 4 measurement points (linearity)
- Grey filter
- UV/VIS-standard solutions (e.g. holmium oxide solution)
- Specifications for control standard for standard parameters including tolerance specifications
- Matrix check and increase procedure with measurement value calculation and retrieval rates
Batch certificates ensure the quality of each individual test batch and help with saving the plausibility of results. Data management 2 USB interfaces provide data exchange (by USB-stick or via USB-hub in a bigger PC environment). The exchange is bi-directional and makes simple handling for saving and updating possible: - Measurement data records and PDF files
- Spectra and kinetics data
- Software updates
- Method updates
- PC-software for data management
By means of a bar code reader, also uncoded tests and sample names can be read. In addition, an RS 232 interface provides another connection to peripheral devices. User-friendly operation - User guidance on the screen
- Function keys F1-F4 for quick working with menu-dependent function assignment
- Frequent functions in direct access (Print, Save)
- Automatic list of favourites for test record
- Selection lists
- Data filter for selective data editing
| Article | Order No. | |
(3) | photoLab® 6100 VIS | 10 81 20201 | |
| Spectral photometers for systematic and spectral analysis from 320-1100 nm (specify power supply) | |
(4) | photoLab® 6600 UV-VIS | 10 81 20202 | |
| Spectral photometers for systematic and spectral analysis from 190-1100 nm (specify power supply) | |
5 Mobile colorimeters: the pHotoFlex® series
The colorimeters of this series convince by their sophisticated technology for use on site, comprising an optional LabStation for easy evaluation and execution of laboratory tasks. A large illuminated graphic display guides the user through all functions. A laboratory station with battery and charging function is available as an accessory for the the basic battery-operated model (4 AA batteries). Routine data measurement and evaluation can then be performed even more conveniently with an external scanner and evaulation software. pHotoflex®STD For all those who only need photometry functions: more than 150 methods. pHotoflex®pH Colorimeter with electrochemical pH and redox option. Additional methods for ammonia and carbon dioxide. pHotoFlex®Turb Same as pHotoFlex pH, plus turbidity measurement from 0 to 1100 NTU / FNU. Photometer functions - 6 wavelengths: 436, 517, 557, 594, 610, 690 nm, LEDs with filter, accuracy < 2 nm
- Extinction range: 0 – 2 E
- 2 cuvette sizes for a large range of concentration: 28 mm, 16 mm; variable cuvette height from 91 to 104 mm for the 16 mm cuvette
- Up to 200 method-related data for a large number of test sets, extendible over the Internet, for drinking- and waste water analytics, CSB determination
- Data memory for 1000 measurements
- 100 own methods
- Coloring measurement according to EN ISO 7887 (exactly 436 nm, 517 nm, 610 nm)
pH functions - pH meter with temperature compensation and 3-point calibration
- pH -2.00 to 16.00 (+/- 0.01), temperature: -5.0 to 100.0 °C
- Automatic buffer recognition: TEC / NIST
Turbidity functions - IR LED according to DIN 27027/ISO 7027
- Measuring range: 0-1100 NTU / FNU
- Resolution: 0-9.99 NTU: 0.01; 10-99 NTU: 0.1; 100-1100 NT: 1.0
- 3-point calibration with standards (0.02 – 10 – 1000 NTU)
| Article | Order No. | |
| pHotoFlex STD, incl. batteries (4 AA) | 10 81 21105 | |
| pHotoFlex pH pocket photometer, incl. batteries (4 AA) | 80 81 51100 | |
| pHotoFlex Turb pocket photometer, incl. batteries (4 AA) | 80 81 51110 | |
Accessories
| Article | Order No. | |
| pHotoFlex rechargeable battery | 80 81 51300 | |
| Rechargeable battery + mains plug for all pHotoFlex models | |
| LabStation | 80 81 51301 | |
| Laboratory station with pHotoFlex software for all pHotoFlex models, incl. rechargeable battery and mains cable, laboratory interface cable (9-pole) - simplified operation for routine measurements
- more functionality (barcode support)
- better input and output of data through pHotoFlex software
| |
| Interface cable AK540/B | 80 81 52842 | |
| Unit/PC (6-pole) via RS232 | |
Accessories pH
6 Reagents for photoLab® and photoFlex® series
Other tests on request, method data can be updated from the Internet. 1) not for photoLab S6 2) not for pHotoFlex®
|
|
|