The single-beam spectral photometer AL800 is equipped with a wide range of pre-programmed methods based on the proven range of AQUALYTIC® tablet reagents, liquid reagents, tube tests and powder reagents (Vario Powder Packs). Additionally it is possible to store user methods by entering Polynomials.
A wavelength scan is performed in 1 nm steps between 330 and 900 nm. Absorption is measured on each wavelength.
Additional features:
- Wavelength scan between 330 – 900 nm
- Kinetics feature
- Use of round vials and rectangular cells of different sizes without adapter
- Updates of new methods and languages via Internet
Preprogrammed measurements: |
Alkalinity-m | 5 – 200 mg/l 5 – 500 mg/l | Iron | 0.1 – 1 mg/l 0.01 – 0.5 mg/l 0.1 – 3 mg/l | Phenole | 0.1 – 5 mg/l |
Alkalinity-p | 5 – 300 mg/l | Iron total | 0.1 – 1.8 mg/l | Phosphate, acid hydrolizable | 0.02 – 1.6 mg/l |
Aluminium | 0.01 – 0.3 mg/l 0.01 – 0.25 mg/l | Coloration spectral absorption coefficient | 0 – 50 m-1 | Phosphate total | 0.02 – 1.1 mg/l 0.07 – 3 mg/l 1.5 – 20 mg/l |
Arsenic | 0.02 – 0.6 mg/l | Urea | 0.1 – 2 mg/l | Phosphonate | 0 – 125 mg/l |
Lead | 0.1 – 5 mg/l | Hardness, total | 2 – 50 mg/l 20 – 500 mg/l | Active Oxygen | 0.1 – 10 mg/l |
Boron | 0.1 – 2 mg/l | Color (Pt-Co scale; APHA) | 0 – 500 mg/l | Acid capacity | 0.1 – 4 mmol/l |
Bromine | 0.1 – 3 mg/l 0.05 – 1 mg/l 0.05 – 6.5 mg/l | Hydrazine | 0.05 – 0.5 mg/l 0.005 – 0.6 mg/l | Silicon dioxide | 0.05 – 3 mg/l 0.1 – 1.6 mg/l 1 – 100 mg/l |
Cadmium | 0.025 – 0.75 mg/l | Iodine | 0.05 – 3.6 mg/l | Nitrogen total | 0.5 – 14 mg/l 5 – 140 mg/l 0.5 – 25 mg/l 5 – 150 mg/l |
Chlorine | 0.1 – 6 mg/l 0.02 – 0.5 mg/l 0.02 – 3 mg/l 0.1 – 10 mg/l 0.02 – 3 mg/l 0.01 – 2 mg/l 5 – 200 mg/l | Potassium | 1 – 10 mg/l | Sulphate | 2 – 100 mg/l |
Chloramine | 0.04 – 4.50 mg/l 0.01 – 0.50 mg/l | Copper | 0.05 – 1 mg/l 0.5 – 5 mg/l 0.05 – 5 mg/l | Sulfide | 0.04 – 0.5 mg/l |
Chlorine dioxide | 0.05 – 1 mg/l 0.05 – 2.5 mg/l | Manganese | 0.2 – 4 mg/l 0.01 – 0.7 mg/l 0.1 – 18 mg/l | Sulphite | 0.04 – 0.5 mg/l |
Chloride | 0.5 – 25 mg/l 5 – 60 mg/l | Molybdate | 1 – 30 mg/l 0.05 – 5 mg/l 0.5 – 66 mg/l | Suspended solids | 0 – 750 mg/l |
Chromium | 0.005 – 0.5 mg/l 0.02 – 2 mg/l | Nickel | 0.02 – 1 mg/l 0.2 – 7 mg/l | Surfactants (anionics) | 0.05 – 2 mg/l |
COD | 0 – 150 mg/l 0 – 1500 mg/l 0 – 15000 mg/l | Nitrate | 1 – 30 mg/l 0.5 – 147mg/l | TOC | 50 – 80 mg/l |
Cyanide | 0.005 – 0.2 mg/l 0.01 – 0.5 mg/l | Nitrite | 0.01 – 0.5 mg/l 0.03 – 0.6 mg/l 0.3 – 3 mg/l 0.01 – 0.3 mg/l | Turbidity | 5 – 500 |
Cyanuric acid | 0 – 160 mg/l | Ozone | 0.02 – 0.5 mg/l 0.02 – 1 mg/l | Hydrogen peroxide | 0.01 – 0.5 mg/l 0.03 – 1.5 mg/l |
DEHA | 0.02 – 0.5 mg/l | pH value | 6.5 – 8.4 | Zinc | 0.02 – 0.5 mg/l |
The spectrophotometer AL800 is coomprised in an entire waste water setup. Comprising the thermoreactor AL125, reagents for COB, ammonium, nitrate, nitrite, nitrogen, phosphate, and all required accessories, this setup is immediately ready for use.