Main -> Glass construction, glass equipment -> Special equipment -> Gas distributors
Nitrogen Vacuum Workplaces, Rettberg
Nitrogen Vacuum Workplaces made of borosilicate glass 3.3

Complete unit (building kit) consisting of several parts for assembly in various ways (left- or right-hand corner arrangements or in a straight line side by side), consisting of:

ArticleOrder No.
(1)N2/vacuum interchangeable rack13 70 79100

4 two-way stopcocks (hollow) joint 21.5 / 6 mm, with glass hose connections 12 mm. Connection to double cooling trap KF 25 mm. Connection to N2 with link KF 16 mm to hose connection 12 mm. Both connections are interchangeable on the right or left, with dummy cap always placed opposite. Delivered complete with flange materials.
Dimensions: Overall height: approx. 19 cm, length: approx. 50 cm.

 
ArticleOrder No.
(2)Vacuum double cooling trap13 70 79500

directly connected, side connections KF 25 mm, lower parts approx. 500 ml capacity with KF 50 mm. Length of lower parts approx. 230 mm. Delivered complete with flange materials.
Dimensions: Overall height approx. 45 cm, length approx. 35 cm, assembly height above work top: 32 cm (from bottom of cooling traps).

 
ArticleOrder No.
(3)Connecting piece for straight set-ups13 70 79616

between interchangeable racks and the double cooling trap 2 × KF 25 mm, with KF 16 mm for Pirani sensor and blind cap. Delivered complete with flange materials.
Dimensions: length: approx. 11 cm.

 
ArticleOrder No.
(4)Connecting piece for corner set-ups13 70 79625

between interchangeable racks and the double trap 2 × KF 25 mm, with KF 16 mm for Pirani sensor and blind cap. Delivered complete with flange materials.
Dimensions: Length of legs: A = 10 cm, B = 20 cm.

 
ArticleOrder No.
(5)Vacuum shut-off valve 0-15 mm13 70 79715

removable with KF 25 for connecting on the suctions side to the double cooling trap, with additional valve 0 to 6 mm and hose connection Olive 10 mm for vacuum or venting, connection to vacuum line KF 25 mm (e.g. for metal hose), removable link KF 25 mm to hose connection 16 mm (clear width 9 mm). Delivered with flange materials.



Optional
ArticleOrder No.
(6)N2/vacuum interchangeable rack13 70 79200

4 two-way valves (vacuum 0 to 12 mm, N2 0 to 6 mm), working connections: 2 × hose 13 mm, 1 × conical joint 14.5, 1 × conical joint 29 (removable with small flanges; other set-ups possible on request). Connection to double cooling trap KF 25 mm. Connection to N2 with link KF 16 mm to hose connection 12 mm. Connections for N2 and vacuum are interchangeable on the right or left, with dummy cap always placed opposite. Delivered complete with flange materials.
Dimensions: Overall height: approx. 25 cm, length: 50 cm



Further accessories and spare parts
ArticleOrder No.
Trap bottom, KF 50 mm13 70 79550
Pirani vacuum gauge13 70 79810

with digital indicator, matching sensor and connecting cable.

Set of Dewar vessels13 70 79820

suitable for cooling traps, with coating.

Working connection with tube connector 12 mm, with glass flange13 70 79312
Working connection with cone NS 14.5, with glass flange13 70 79314
Working connection with cone NS 29, with glass flange13 70 79329
Dummy cap KF 16 mm13 70 79416
Dummy cap KF 25 mm13 70 79425



(A variable stand system and suitable tripod materials for assembling the system are available on request.)